Defense Logistics Agency DLA logo and Link to DLA website DLA logo and Link to DLA website DEFENSE LOGISTICS AGENCY DLA Land and Maritime Qualification Part Search

Company Location Information

Microsemi HRG (CAGE Code:43611)
6 Lake Street, Lawrence, MA, 01841, US

Company Contact: Ms. Beth Parker,Phone: 978-620-2636,Fax: 978-774-0939
Land and Maritime Contact:Phone: 614-692-1766, Fax: 614-693-1658, E-mail: vqh.jms@dla.mil


Quality Management (QM) Program:Non-TRB
Periodic Inspection System:Option 2
ISO 9000 System:

Technologies:Point of Load Regulator



Classes: Class K, Class H, Class E

Qualification Letters: VQ(VQH-12-025103),VQ(VQH-17-031105),VQ(VQH-15-029477),VQ(VQH-15-029474),VQ(VQH-15-028926),VQ(VQH-20-034899),VQ(VQH-16-029949),VQ(VQH-13-027082),VQ(VQH-15-029572)


Substrate Fabrication Flows: N/A
Substrate Fabrication: Purchased Plated Up Copper on BeO, 1 Conductor Level(s); Purchased Direct Bonded Copper on BeO, 1 Conductor Level(s)


Assembly Flows: T3-HPG-FC001
Substrate Attach: Solder
Element Attach: Nonconductive Epoxy,Conductive Epoxy,Solder
Add-on Elements: Inductors,Chip Capacitors,Unpackaged Die,Chip Resistors
Wire Bonding: Gold,Aluminum


Packages: Metal Package, Flatpack, Seam Weld, 3.64 Seal Perimeter, 16 Leads, Gold Lead Finish


Notes:

1/ The QML listing can be expanded provided appropriate qualification testing is performed and passed. Therefore the manufacturer may accept an order for compliant product not covered by his QML listing, but shall not ship the compliant product until the testing has been successfully completed.

2/ Package seal perimeter is listed by largest perimeter successfully tested in inches.

3/ Package lead counts are listed by maximum number of leads covered by qualification.

6/ Class E devices are devices, which meet all of the requirements of one of the other classes (K, H, or G), with some exceptions taken. Therefore any manufacturer qualified to G, H or K is eligible to produce and mark product as compliant to class E.